EMC TEST Design (1)
EMC TEST Design (2)
Detectus
Laplace
MIT3201

AC 1000 | SA1004 Convertisseur 1 GHz-4 GHz  

AC 2000

AC2000 Analyseur de puissance, d'harmoniques et flickers


AC2000

Mesures de puissance , rapides et de haute qualité.
Analyses des harmoniques en conformité avec la norme EN61000-3-2.
Analyses des flickers en conformité avec la norme EN61000-3-3.


Présentation

The AC2000 is a fast, easy to use mains and harmonics analyser with full graphical display. It is capable of continuous real-time analysis of both voltage and current.
As a general purpose mains analyser it can measure Watts, VA Vrms, Vpk, Arms, Apk, Crest factors, THD, Power factor, Frequency and Inrush current.
As a harmonics analyser it is a quick and convenient instrument for pre-compliance measurements using normal mains supply and is capable of full compliance measurements to EN61000-3-2 in conjunction with a suitable power source.
Capabilities include real-time Class D evaluation and visual display, continuous automatic calculation of harmonic limits to EN61000-3-2, inrush current analysis, and timed test sequences with analysis of fluctuating harmonics.
As an option, the AC2000 can be operated as a conformance quality flicker meter in conformance with EN60868 and EN61000-3-3.
A printer interface is included for record keeping and archiving, along with an RS-232 interface and an optional IEEE-488 interface for use with PC based software or as part of a GPIB system.


Analyseur de puissance de haute performance

The AC2000 is a high speed, high accuracy ac power analyser for single phase supplies of up to 16 amps RMS.
The supply to be measured is connected via a dedicated input cable independently of the supply to the instrument.
The output to the load is via a front panel mounted standard’ mains connector. A wide range of power connectors is available including most European national types.The AC2000 can measure Watts, VA, Volts rms, Volts peak, Amps rms, Amps peak, Crest factors, THD, Power factor, Frequency and Inrush current.
The large display can show multiple parameters simultaneously along with graphical representations of voltage and current waveforms.


Analyseur de conformité des harmoniques

From 1st January 2001 all electrical equipment sold within the EEC will have to comply with legislation relating to the harmonics content of the current waveform.
The AC2000 has been designed to make these measurements both quick and simple. It measures harmonics from the 1st to the 40th and updates the display in real time.
It is suitable for pre-compliance measurements using a normal mains supply and is capable of full compliance measurements to EN61000-3-2 in conjunction with a suitable power source (such as the AC1000 ).
Capabilities include real-time Class D evaluation and visual display, continuous automatic calculation of harmonic limits to EN61000-3-2, inrush current analysis, and timed test sequences with analysis of fluctuating harmonics.


Mesure de conformité des flickers

The AC2000 has the optional capability to operate as a compliance quality flicker meter in conformance with EN60868 and EN61000-3-3.
A current measurement method can be used rather than voltage measurement thus eliminating the need for a reference impedance.
Flicker severity can be measured in terms of Pst and Plt with analysis periods variable between 5 minutes and 2 hours.
The graphical display can show Cumulative Probability, Voltage Deviation Failure as well as Pst values.

Une large gamme d'interfaces
A printer interface is included for record keeping and archiving, along with RS-232 (standard) and IEEE-488 (optional) interfaces for use with PC based software or as part of a GPIB system.
Software is also available that enables results to be displayed, recorded and documented using a PC.


CARACTERISTIQUES TECHNIQUES

Mains Analyser   
Measurement Circuit:  Single Phase with standard mains connector. 
Current Rating:  16A rms continuous, or national connector rating if lower. 
Voltage Ranges:  115V (±200V pk) 230V (±400V pk). 
Current Ranges:  ±24mA pk to ±400A pk in fifteen 2:1 ranges 
Frequency Range:  45 - 66 Hz.  
Shunt Resistance:  3m ohms.  
Sampling Rate:  300 points per cycle.  
Basic Accuracy:  <0.2%.  
Measured Parameters:  Vrms, Vpk, Arms, Apk, Crest factors, THD, W, VA, Power factor, Frequency, Inrush current.  
Monitor Outputs:  Re-constructed Voltage and current signals  
Harmonics Analyser   
Measurements:  1st harmonic to 40th harmonic.  
Current Rating:  16A rms continuous, or national connector rating if lower.  
Voltage Ranges:  115V (±200V pk) 230V (±400V pk).  
Current Ranges:  ±24mA pk to ±400A pk in fifteen 2:1 ranges  
Frequency Range:  45 - 66 Hz.  
Shunt Resistance:  3m ohms.  
Sampling Rate:  300 points per cycle.  
Basic Accuracy:  Better than 5% of limit or 0.2% of selected range whichever is the greater.  
Display Modes:  Numeric readout of parameters. Graphical Waveform display with accumulate and max.
Hold facilities and class D mask.
Tabular and Histogram harmonic analysis with comparison to limits in the standards.  
Flicker Meter (Option)   
Measurement:
 
Pst and Plt to EN60686 and EN61000-3-3.
 
Current Rating:

 
16A rms continuous, or national connector rating if lower. 
Voltage Ranges:
 
115V (±200V pk) 230V (±400V pk). 
Current Ranges:
 
±24mA pk to ±400A pk in fifteen 2:1 ranges 
Frequency Range:
 
45 - 66 Hz. 
Shunt Resistance:
 
3m ohms. 
Sampling Rate:
 
300 points per cycle. 
General   
Display:
 
320 x 240 pixel backlit LCD. 
Interfaces:
 
Parallel Printer, RS232, Optional IEEE-488 (GPIB). 
Instrument Supply:
 
230V or 115V ±14%, 48 to 65 Hz.
 
Operating Range:
 
+5°C to 40°C, 20-80% RH. 
Storage Range  -10°C to +60°C  
Dimensions:  305 x 148 x 220mm (WxHxD)  
Weight:  4.2kg 
Safety:
 
Complies with EN61010-1
EMC Compliance:
Complies with EN61326-1  
   



Contact Mentions légales